Vue de la page 7
10
SPECIFICATIONS
Measurement Conditions (unless otherwise specified):Tone controls
centered; Line voltage 120 Vac, 60 Hz (SCM262) or 230 Vac, 50 Hz
(SCM262E);
full gain; 1 kHz, one channel activated;
source impedances:
Mic 150
; Line/Aux 40
, terminations: Line/Mic/Aux 20 k

Frequency Response (Ref 1 kHz, channel and master controls
centered)
MIC/LINE Inputs: 150 Hz to 20 kHz 2 dB
AUX Inputs: 20 Hz to 20 kHz 2 dB
Low-Cut Filter (Microphone inputs only)
3dB down at 80 Hz, 6 dB/octave
Voltage Gain (typical, controls full clockwise)
Inputs
Outputs
Total Harmonic Distortion
<0.25% at +4 dBu output level, (through 22 Hz—22 kHz filter; MIC Input
1 and Master at center, all other controls full counterclockwise)
Equivalent Input Noise (150 source; A-Weighted)
–128 dBV
Output Noise (channel controls full counterclockwise,
A-Weighted)
Master full counterclockwise .................................................. –95 dBV
Master full clockwise .............................................................. –59 dBV
Common Mode Rejection
>70 dB at 1 kHz
Polarity
All inputs to all outputs are non-inverting.
Overload and Shorting Protection
Shorting outputs, even for prolonged periods, causes no damage.
Microphone inputs are not damaged by signals up to +10 dBV; Line and
Aux inputs by signals up to +28 dBV
Equalization
Bass (Low-frequency shelving,
corner frequency at 250 Hz)
 6 dB
Treble (High-frequency shelving,
corner frequency at 4 kHz)
 6 dB
Ducking
Mic channels 1 and 2 Levels .................................... –20 dB or – dB
Activation time ............................................................. 10 ms (typical)
Mic Deactivation time ........................................................ 2 s (typical)
Jukebox Mute Deactivation Time .................................... 30 s (typical)
Phantom Power
12 Vdc open-circuit through 680 resistors
Operating Voltage
SCM262: 100—120 Vac, 50/60 Hz, 60 mA
SCM262E: 220—240 Vac, 50/60 Hz, 30 mA
Temperature Range
Operating...............................................–7 to 49 C (20 to 120 F )
Storage.................................................–29 to 74 C (–20 to 165 F)
Overall Dimensions
43 x 218 x 162 mm (1.72 x 8.60 x 6.37 in.)
Net Weight:1.1 kg (2 lbs, 5 oz)
Certifications
SCM262: UL, cUL listed by Underwriters Laboratories.
SCM262E: Conforms to European Union directives, eligible to bear CE
marking; Certified to EN 60 065; meets European Union EMC Immunity
Requirements (EN 50082-1: 1992, EN 50082-2: 1992)
Conforms to European Regulation (EC) No. 1275/2008, as amended.
The CE Declaration of Conformity can be obtained from Shure
Incorporated or any of its European representatives. For contact
information please visit www.shure.com
The CE Declaration of Conformity can be obtained from:
ww.shure.com/europe/compliance
Authorized European representative:
Shure Europe GmbH
Headquarters Europe, Middle East & Africa
Department: EMEA Approval
Jakob-Dieffenbacher-Str. 12
75031 Eppingen, Germany
Phone: 49-7262-92 49 0
Fax: 49-7262-92 49 11 4
Replacement Parts
Knob, Master (blue) ............................................... 95B8752
Knob, Channel Gain (white)................................... 95A8752
Line (Power) Cords:
SCM262: 100—120 Vac (US/Canada) ............. 95B8762
SCM262E: 220—240 Vac (EU)......................... 95B8778
Fuse:
SCM262 (5x20 mm, 250V,
100mA, time delay) ............................................ 80Z730
SCM262E (5x20 mm, 250V,
40mA, time delay) .............................................. 80M258
Hardware Kit .......................................................90AW8100
Link Bars (Bracket) ................................................ 53B8443
Single Mount Bracket............................................. 53A8484
Dual Mount Bracket .............................................. 53E8484
Optional Accessories
Line (Power) Cord, 230—240 Vac (UK)................. 95A8713
Service Statement
For additional service or parts information, please contact Shure's
Service department at 1-847-600-8699. Outside the United States,
please contact your authorized Shure Service Center.
Output
Input Mic Line Aux
Low-impedance mic
(150 )
32 dB 72 dB 60 dB
Line –9 dB 31 dB 19 dB
Stereo –5 dB 35 dB 23 dB
Impedance
Input
Designed
for use with
Actual
(typical)
Input
Clipping Level
Mic (XLR) <600 1.4 k –16 dBV
Line <10 k 155 k +24 dBV
Stereo <2 k 21 k >28 dBV
Impedance
Output
Designed for
use with
Actual
(typical)
Output
Clipping Level
Mic > 600 3 –22 dBV
Line >5k 300 +18 dBV
Aux 10 k 1.5k +5 dBV